Place of Origin: | Sichuan, CHINA |
---|---|
Brand Name: | IOTROUTER |
Certification: | CE FCC RoHs |
Model Number: | ZHC1661 |
Minimum Order Quantity: | 1PCS |
Price: | USD35~39.9/PCS |
Packaging Details: | 270*180*55mm CARTON PACKAGE |
Delivery Time: | 1 WEEK |
Payment Terms: | L/C, T/T, Western Union |
Supply Ability: | 50000PCS/MONTH |
Material: | Galvanized Steel Sheet | Interface: | RS485/4AI/2AO |
---|---|---|---|
Protocol: | MODBUS TCP/RTU MQTT | Product Name: | Modbus TCP Serial To Ethernet |
Function: | Data Transmission | Application: | Industrial Monitor |
Working Voltage: | 12V | Module Type: | Ethernet |
Customized: | Support | Color: | Black |
High Light: | TCP Serial To Ethernet Converter,serial to ethernet converter Rtu,Analog Input Output Monitor Rtu |
Modbus TCP Serial To Ethernet Rtu With Analog Input Output For Industrial Monitor
Parameters of Serial to Ethernet Modem ZHC1661
Introduction of Serial to Ethernet Modem ZHC1661
Product model: ZHC1661, the network is Ethernet, RS485/4AI/2AO interface is provided.
Special functions: AO remotely follows AI, 4-20mA analog quantity automatic report, 12-bit sampling accuracy.
Protocol: Support Modbusr RTU/TCP adaptive.
Industrial-grade quality: can work normally at -20℃~+60℃, galvanized steel plate material, dual watchdogs
Application: telecommunication equipment room monitoring, reservoir water level monitoring, boiler room temperature management monitoring, etc.
ZHC1661 supports setting 8 logics between devices.
Forward follow: DI is closed and DO is closed
Reverse following: DO is open when DI is closed, and DO is closed when DI is open
AO follows AI: AO output value = AI input value
AI voluntarily report description:
Disable reporting mode: Report all AI values cyclically according to the set cycle.
Report within the interval: When the set AI channel value enters the interval from outside the interval, all AI channel values are reported immediately and the cycle time is reset.
Report outside the interval: When the set AI channel value enters the interval from inside the interval, all AI channel values will be reported immediately and the cycle time will be reset.
The default IP address of ZHC1661 is 192.168.0.65. During configuration, the IP of the computer and ZHC1661 must be set to the same IP address range, otherwise the device and the computer cannot communicate. ZHC1661 has a built-in parameter configuration webpage, users do not need to pay attention to device related holding registers, only need to understand the reported data of the device.
After setting the ZHC1661 parameters, connect the ZHC1661 to the network with a network cable. After the device is powered on, observe that the WORK indicator should flash for 3 seconds, indicating that the network hardware environment of the device is normal and data interaction is possible.
Application of Serial to Ethernet Modem ZHC1661
Industrial Automation
Suitable for industrial automation production lines and can monitor industry chain data in real time. Count the number of products by pulse counting.
Traffic Lights Management System
Unified management of street lamps to achieve remote monitoring and intelligent management of lighting. Reduce manpower management costs and improve maintenance efficiency.
|
ZHC1661 |
RS485 Modbus |
√ |
RS485 Automatic Acquisition |
√ |
Virtual Serial Port |
√ |
Connfiguration Software |
√ |
Threshold Report |
√ |
Customize the Follow Logic of Ports |
√ |
MQTT/Modbus RTU/TCP |
√ |